Electronic Infusion Pumps

BodyGuard 121 Twins

The BodyGuard 121 Twins infusion pump is universally used for two-channel infusion therapy in both the hospital and home environment. The construction of the device ensures outstanding linearity and easy handling.


Mobile two-channel infusion therapy Because of the simultaneous application of two infusion solutions, complex therapies and new treatment approaches are possible with a mobile infusion pump.

Additional safety due to key-and-lock principle The rising complexity of therapies can lead to increased error rates. Therefore, the BodyGuard 121 Twins infusion pump and TW2010 Sets are equipped with an elaborate key-and-lock principle which creates additional safety for patient and user. This can be achieved due to the combination of two features: a safety adapter which is mounted in the doors of the pump and which limits the operation of the particular channel to appropriate equipped TW2010 Sets as well as a big key on the TW2010/5 Set which can only be inserted into the pump if the safety adapter is removed. Consequently, set mix-ups and the operation of an "inappropriate" TW2010 Set in a not according to the therapy adjusted channel can be prevented.

Cost savings and weight reduction The use of only one mobile infusion pump with a double lumen set leads to cost savings compared to a therapy with two infusion pumps and two sets. In comparison to the use of two pumps there is also a weight reduction of almost 50%.

Outstanding linearity The infusion pump administers continuously with outstanding linearity on both channels. The accuracy is +/- 5%.

Easy to operate The menu navigation and key layout make operating the pump easy and safe.

  • Flow rate: 0,1 - 1.200 ml/h; 0,0 - 100 ml/h in PCA program
  • Control display for battery status and charge level
  • Event log for documentation of pump history
  • Individually adjustable therapy due to extensive range of accessories and consumables
  • Six therapy options: continuous, TPN, 25 doses, PCA, intermittent, dose
  • Extensive safety features: self-cancelling occlusion alarm; air bubble identification using ultrasound; alarms for malfunctions and access restrictions, low and empty battery as well as door open; safety adapter in pump doors
  • Use of glass bottles possible due to a special set with vented spike and drip chamber (TW201/6)

Caesarea Medical Electronics GmbH

23 Staufenberg st.

72805 Lichtenstein, Germany

  • Flow rate: 0.1 - 1,200 ml/h; 0.0 - 100 ml/h in PCA mode
  • Accuracy: +/- 5%
  • Volume: 0.1 - 9,999.0 ml
  • KVO rate: 0.1 - 5.0 ml/h
  • Pressure: max. 990 mmHg or 19.9 psi adjustable
  • Air: ultrasound sensor, threshold value 0.1 -1.0 ml
  • Pump system: piston mechanism
  • Alarms: end program; battery low; battery empty; air in line; occlusion; door open; pump locked; lock mode; pump unattended; error; check set
  • Power supply: 110 - 240 V; 50/60 Hz; 0.3 A max.
  • Battery: Li-Ion; 3,000 mAh
  • Size: 89 x 149 x 41 mm (W x L x H)
  • Weight: 280 g (without battery), 580 g (with battery)
  • Parenteral nutrition/TPN
  • Anglestics therapy/PCA
  • Chemotherapy
  • Chronotherapy/circadian therapy
  • Emergency medical aid
BodyGuard 121 Twins
REFVersionMarkingPU
250121Incl. battery, cable, chargerBodyGuard 121 Twins1
 
 
BodyGuard 121 Twins - Electronic Infusion Pumps
pfm medical wordwide

You have questions? Call our customer service & sales support under. +49 (0)2236 9641-0