Stents

EVO® Target – Peripheral Stent

The particularly high radial force is the distinguishing feature of the nitinol stent implantation system. The EVO® Target system has an ergonomic applicator handle for single-handed operation and optimum user friendliness and control when releasing the stent.

High radial force  The EVO® Target is configured for particularly high radial force.

Optimum handling and control  The gummed thumb wheel with grid pattern provides ideal handling and control, even under difficult surgical conditions. The surgeon can see the length of stent released at all times.

Optimum insertion and very high kink resistance  Thanks to the latest catheter technology, the 6 F system with a reinforced, braided sheath meets the most stringent insertion and kink-stability standards.

  • Highly flexible, kink-resistant over-the-wire catheter system
  • Braided 6 F catheter for better insertion and better kink-resistance properties
  • Atraumatic catheter tip
  • No-jump properties
  • Ergonomic application handle for single-handed operation
  • Gummed thumb wheel with grid pattern for releasing the stent
  • Precise, controlled stent release
  • Centimetre scale
  • Stent design: zig-zag pattern in helical design
  • Integrated, radiopaque tantalum markers

pfm medical ag

Wankelstraße 60

50996 Köln, Germany

  • Stent design: EVO® Target
  • Stent length: 20–100 mm
  • Stent diameter: 4–10 mm
  • Catheter 6 F: braided, 0.035“ guide wire
  • Catheter length: 85 cm
  • Applicator handle with thumb wheel for releasing the stent
  • Flexible system with good insertion properties on standard 0.035“ guide wires
  • Extremely kink-resistant

The high-performance, flexible nitinol stent implantation system for vascular and biliary procedures. Available as flexible, kink-resistant 6 F catheter systems. With its reinforced, braided sheath channel, the 6 F system satisfies the most stringent insertion and kink-stability standards.

The open cellular structure of the EVO® Target nitinol stent with its zig-zag pattern in helical design is configured for particularly high radial force. Thanks to its no-jump properties, EVO® Target enables a precise, controlled positioning of the stent. EVO® Target displays only minimum shrinkage, so the in vivo dimensions correspond exactly to the selected specifications.

The ergonomic applicator handle for single-handed operation provides optimum manoeuvrability and control when releasing the stent. A centimetre scale on the handle monitors the length of stent released. The rubberised thumb wheel with grid pattern guarantees optimum handling and control under surgical conditions.

EVO® Target – Peripheral Stent
REFIntroducer sheathGuide wireUsable lengthStent diameterStent lengthPU
0662-050506 F0,035"85 cm5 mm50 mm1
0662-051006 F0,035"85 cm5 mm100 mm1
0662-060206 F0,035"85 cm6 mm20 mm1
0662-060306 F0,035"85 cm6 mm30 mm1
0662-060406 F0,035"85 cm6 mm40 mm1
0662-060506 F0,035"85 cm6 mm50 mm1
0662-060606 F0,035"85 cm6 mm60 mm1
0662-060706 F0,035"85 cm6 mm70 mm1
0662-060806 F0,035"85 cm6 mm80 mm1
0662-060906 F0,035"85 cm6 mm90 mm1
0662-061006 F0,035"85 cm6 mm100 mm1
0662-070206 F0,035"85 cm7 mm20 mm1
0662-070306 F0,035"85 cm7 mm30 mm1
0662-070506 F0,035"85 cm7 mm50 mm1
0662-080506 F0,035"85 cm8 mm50 mm1
 
 
EVO® Target – Peripheral Stent - Stents
40 Years Quality and Experience

You have questions? Call our Customer Solutions team under. +49 (0)2236 9641-0