TiLOOP® LLS Dubuisson and LLS H Dubuisson

TiLOOP® LLS Dubuisson and LLS H Dubuisson
Image similar
The titanised mesh implant TiLOOP® LLS Dubuisson is used for laparoscopic lateral suspension (LLS) for uterus preservation and the TiLOOP® LLS H Dubuisson after hysterectomy. Laparoscopic lateral suspension (LLS) according to Dubuisson results in safe, successful defect therapy in both the apical and anterior compartments. LLS offers an alternative to sacrocolpopexy.
Made in Germany

Benefits

Safe
Compared to sacrocolpopexy, anchoring the mesh at the Os sacrum is no longer required. Therefore, the risk of injury in this area is avoided.1,2

  • No foreign material on the periosteum, no danger of periostitis
  • Lumbar pain is avoided
  • Iliac blood vessels, aorta, vena cava and ureter in the region of the promontory are not injured
  • Minimised risk of irritations or injuries of the hypogastric plexus
  • Minimal risk of gut-mesh adhesion
  • Minimal risk of erosion


Anatomically and symptomatically successful

  • Cranial central rather than posterior apex suspension: physiological suspension compared to sacrocolpopexy
  • Tension-free lateral suspension without anchoring
  • In the anterior and apical compartments, 93.6 % success rate1
  • Minimal dyspareunia rate1,3
  • Positive effect on obstipation problems


Simple, standardised surgical technique

  • Minimal opening of the peritoneum
  • Simple sub peritoneal tunnelling, no anchoring of the mesh arms to ligamentous structures
  • No preparation of the sacral promontory or other ligamentous connections
  • Individual, tension-free adjustment of the mesh after lateral, extraperitoneal positioning of the mesh arms


[1] Veit-Rubin, N., et al., Patient satisfaction after laparoscopic lateral suspension with mesh for pelvic organ prolapse: outcome report of a continuous series of 417 patients. Int Urogynecol J, 2017. 28(11): p. 1685-1693
[2] Dubuisson, J.B., et al., Treatment of genital prolapse by laparoscopic lateral suspension using mesh: a series of 73 patients. J Minim.Invasive.Gynecol., 2008. 15(1): p. 49-55
[3] Dubuisson, J., et al., Laparoscopic repair of vaginal vault prolapse by lateral suspension with mesh. Arch Gynecol Obstet, 2013. 287(2): p. 307-12

Product Details

  • Monofilament fabric
  • Laser-cut, atraumatic edges
  • Non-resorbable

Technical Data

  • Material: Titanised type 1a polypropylene mesh
  • Pore size: 1 mm
  • Product weight: 65 g/m²
  • Length: 51.5 cm

Manufacturer

  • pfm medical titanium gmbh, Südwestpark 42, 90449 Nuremberg, Germany

Ordering Information

Article numberMarkingApplicationDelivery unit (VPE)
6000745 TiLOOP® LLS Dubuisson For uterus preservation 1 pcs
6001358 TiLOOP® LLS H Dubuisson After hysterectomy 1 pcs