TiLOOP® PRO PLUS P

The TiLOOP® PRO PLUS P Transvaginal Descensus Repair System is suitable for the total elevation of the pelvic floor in posterior pelvic organ prolapse (rectocele or enterocele). Das PLUS-System und die hydrophile, titanisierte Netzoberfläche machen es einzigartig. The PLUS System and the hydrophilic, titanised surface of the mesh make it unique.
Made in Germany

Benefits

Unique PLUS System
With the PLUS-System, which consists of a catheter and loops, the mesh arms can be positioned atraumatically and adjusted bi-directionally: best prerequisites for tension and fold-free insertion of the mesh.

Reduced Risk of Inflammation
Compared to simple polypropylene, the hydrophilic, titanised surface represents a lower risk of inflammation — and therefore less scar formation.1

By urogynaecologists, for urogynaecologists
All TiLOOP® mesh implants were developed together with urogynaecologists and are 100% Made in Germany.

[1] Scheidbach et al. In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty. Surg Endosc (2004) 18: 211–220

Product Details

Technical Data

  • Content: 1 Mesh, 4 Catheters, 4 Snares
  • Material: Titanised type 1a polypropylene mesh
  • Pore size: 3 mm
  • Product weight: 24 g/m²

Knowledge

Surgery Video
Upon request, we will send you a video demonstrating the implantation of the product.

Highest demands on the material
In addition to the skills of the surgeon, the quality of the mesh material determines the quality of a lasting and anatomically stable descensus repair. TiLOOP® mesh implants are made of Type 1a polypropylene mesh (macroporous & monofilament)1 with a titanised, hydrophilic surface. Compared to simple polypropylene, this offers a number of advantages, which are already known in the use of titanised mesh implants for hernia surgery, such as:

  • better cell growth2
  • lower risk of inflammation3
  • less scarring3
  • less shrinkage of the mesh4


[1] Klinge et al. Modified classification of surgical meshes for hernia repair based on the analyses of 1,000 explanted meshes. Hernia (2012) 16: 251–258
[2] Lehle K. Lohn S., Verbesserung des Langzeitverhaltens von Implantaten und anderen Biomaterialien auf Kunststoffbasis durch plasmaaktivierte Gasphasenabscheidung (PACVD), Abschlussbericht Forschungsverbund “Biomaterialien (FORBIOMAT II)”, 149–173, 2002
[3] Scheidbach et al. In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty. Surg Endosc (2004) 18: 211–220
[4] Scheidbach et al. Influence of Titanium Coating on the Biocompatibility of a Heavyweight Polypropylene Mesh. Eur Surg Res 2004; 36: 313–317

Manufacturer

  • pfm medical titanium gmbh, Südwestpark 42, 90449 Nuremberg, Germany

Ordering Information

Article numberMarkingDelivery unit (VPE)
6001341 TiLOOP PRO PLUS P 1 pcs