The disposable infusion pump TUORen Hard Shell with a hard case has a specially designed balloon-like reservoir that is filled with the drug or fluid intended for infusion. This balloon exerts mechanical pressure thereby administering the liquid based medication through a flow restrictor creating the pre-determined flow rate. The entire unit is sterile and is intended for single use only. The device is designed to deliver the nominal volume within ±10% (CBI, CBI+PCA) or ±15% (MR) of the nominal infusion time.

Benefits

  • Sturdy and dimensionally stable case: The hard case protects the silicone reservoir from external influences.
  • Easy filling and use
  • No battery or power supply required
  • Comfortable for patients
  • Silicone reservoir allows air to dissipate
  • Extendable telescopic core
  • Air and particle filter
  • DEHP-free
  • Latex-free
  • Sterilised with EO valid for 5 years

Technical Data

  • Dimensions: between 116.29 × 48 mm (60 ml) and 219.91 × 66.5 mm (275 ml)
  • Weight: between 57 g (60 ml) and 176 g (275 ml)
  • Length of infusion tube: 1,370 mm (depending on type)

Knowledge

The disposable infusion pumps are designed for patients requiring intravenousIntravenous (from the Latin "intra" (inner, inside) and "vena" (vein)) refers, e.g., to the administration of a medication via a vein., percutaneousPercutaneous means “performed through the skin”. (Latin: "per" - through & "cutis" - skin), subcutaneous, intraoperative sites or epidural administrationMedical term for administering or dispensing medication to patients. of medications. Medications that can be infused include analgesics, chemotherapeutics, antibiotics, antiviral drugs and infusion for re-hydration.

It is available in three types:
Continuous Basal Infusion (CBI type): The CBI type has a micro-flow control tube that regulates the flow rate, enabling medication delivery at the intended rate.The CBI type has a micro-flow control tube that regulates the flow rate, enabling medication delivery at the intended rate.
Patient-Controlled Analgesia (CBI+PCA type): The CBI+PCA type has an additional bolus function allowing the patient to self-administer an additional dose according to their pain level.The CBI+PCA type has an additional bolus function allowing the patient to self-administer an additional dose according to their pain level.
Multirate (MR type): The MR type has an additional flow rate regulating device providing four different flow rates to choose from.The MR type has an additional flow rate regulating device providing four different flow rates to choose from.

Instructions for use

  • Accuracy is affected by temperature, fill volume, height and viscosity of diluent
  • Consider your local disposal guidelines

Manufacturer

  • Europ. Bevollmächtigter: MedNet EC-REP GmbH, Borkstraße 10, 48163 Münster, Germany
  • Henan Tuoren Medical Device Co.Ltd., Weiyuan Industrial Zone, Menggang, Changyuan County, 453400 Henan, China

Ordering Information

Article numberFlow rateVolumeBolusLocking timeInfusion timeDelivery unit (VPE)
CBI-002-060 2 ml/h 60 ml 30 h 100 pcs
CBI-002-100 2 ml/h 100 ml 50 h 10 pcs
CBI-002-275 2 ml/h 275 ml 137.5 h 50 pcs
CBI-003-150 3 ml/h 150 ml 50 h 5 pcs
CBI-004-100 4 ml/h 100 ml 24 h 10 pcs
CBI-005-060 5 ml/h 60 ml 12 h 10 pcs
CBI-005-275 5 ml/h 275 ml 55 h 5 pcs
CBI-008-100 8 ml/h 100 ml 12.5 h 10 pcs
CBI-010-120 10 ml/h 120 ml 12 h 5 pcs
CBI-010-240 10 ml/h 240 ml 24 h 5 pcs
CBI-050-100 50 ml/h 100 ml 2 h 100 pcs
CBI-100-100 100 ml/h 100 ml 1 h 100 pcs
CBI-120-240 120 ml/h 240 ml 2 h 5 pcs
CBI-200-100 200 ml/h 100 ml 30 min 10 pcs
CBI-200-200 200 ml/h 200 ml 1 h 5 pcs
CBI-240-240 240 ml/h 240 ml 1 h 50 pcs
MR-1234-100 100 ml 100 pcs
MR-2345-100 100 ml 100 pcs
MR-2345-275 275 ml 50 pcs
MR-2468-100 100 ml 10 pcs
PCA-1020-150 1 ml/h 150 ml 2 ml 8 min 6.25 d 50 pcs
PCA-2005-100 2 ml/h 100 ml 0.5 ml 15 min 2 d 10 pcs